 |  | |  | Wiring Code | Color | Function | RED | EXCITATION + | BLUE | EXCITATION - | GREEN | SIGNAL + | YELLOW | SIGNAL - |
|
|
|
FOR INDUSTRIAL WEIGHING
This stainless steel shear beam load cell is available with approval according to OIML R60 Class C3 (3000 divisions) and is calibrated in mV/V/Ω by output current matching, which minimises corner correction time on multi-cell systems.
The T85 is fully welded and hermetically sealed to IP68 and IP69K as standard. It can therefore be used in the harshest industrial environments and it’s typically used in weigh platforms, tank and vessel weighing, big bag (FIBC) filling systems, conveyors and machinery using weighing as part of its function. Capacities range from 300kg to 10,000kg.
CAPACITIES (kg): 300, 500, 750, 1000, 1500, 2000, 2500, 3000, 5000
OIML R60. C3 precision class.
Stainless steel. IP68/IP69K protection.
 |  | |  | - The T85 is fully welded and hermetically sealed to IP68 and IP69K as standard. It can therefore be used in the harshest industrial environments and it’s typically used in weigh platforms, tank and vessel weighing, big bag (FIBC) filling systems, conveyors and machinery using weighing as part of its function. Capacities range from 300kg to 10,000kg.
- The Polyurethane cable provides excellent protection against chemicals, UV radiation, rodents and damage from cuts/impacts. ATEX and IECEx approval for all Gas and Dust zones is available as an option. The certification for dust zones 20, 21 and 22 does not require safety barriers, which creates a large cost saving.
For applications in aggressive environments where stress corrosion or acid attack could be a problem, the T85 can be supplied with an optional Parylene coating.
For high temperature applications, an optional version of the T85 is available for operation in environments up to 150°C (continuous temperature).
|
 |  |  | 性能参数 |
|  | - Load Cell Capacity (Emax): 300, 500, 750, 1000, 1500, 2000, 2500, 3000, 5000 (7500, 10000 kg on request)
- Rated Output (Sn): 2 mV/V*
- Accuracy Class according to OIML R60 - number of verification intervals (n): 3000 n.OIML
- Combined Error: < ± 0.017% Sn
- Non-repeatability: < ± 0.015% Sn
- Minimum load cell verification interval (vmin)=Emax / Y: Emax / 10000 kg
- Creep (30 minutes): < ± 0.016% Sn
- Temperature Effect on Zero Balance: < ± 0.002% Sn/˚C
- Temperature Effect on Span: < ± 0.0012% Sn/˚C
- Compensated Temperature Range: -10 to +40 ˚C
- Operating Temperature Range: -30 to +70 ˚C
- Safe Load Limit (Elim): 200% Emax
- Ultimate Overload: 300 %Emax
- Zero Balance: < ± 2% Sn
- Input Resistance: 400 Ω ± 20
- Output Resistance: 350 Ω ± 3
- Insulation Resistance: > 5000 MΩ @ 100V
- Recommended Supply Voltage: 5-15 V
- Maximum Supply Voltage: 15 V
- Environmental protection according to EN 60529: IP68; IP69K
- Cable: 5 m (300 - 5000 kg) or 12 m (7500 - 10000 kg) lenght, 5.7 mm diameter, polyurethane material
- Maximum deflection at Emax: 0.2 - 0.4 mm
- Nominal Shipping Weight: 300 - 2500 kg: 0.9 kg3000 - 5000 kg: 2.2 kg7500 - 10000 kg: 4.3 kg
* Pre-corner adjustment optimised at ± 0.05% by output current calibration
|
|
|