防爆电源模块





ATEX/IECEX TRIPLE ZENER BARRIER FOR LOAD CELLS "ZBA1S"


  ATEX/IECEX TRIPLE ZENER BARRIER FOR LOAD CELLS "ZBA1S"
 

The Zener Barrier ZBA1S is the perfect solution for the connection between a weighing terminal and a weight receiver system in the ATEX ZONE. ZBA1S integrates three barriers in one, protecting the excitation line, signal and sense. This feature makes the installation easier, especially in small spaces. This saves time and money.

TECHNICAL FEATURES

  • Three channels passive zener barrier for power supply, reference and signal. Ex marking: ATEX II (1)G, II (1)D, I (M1)
    IECEx [circuit(s) in zone 0/1/2]

  • Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ +60 °C)

  • Equipped with 3 channels for the protection of the Signal line (CN1/CN4), the Excitation line (CN3/CN6) and the Sense line, for improved signal stability.
  • “SLIM” type case, iper-compact, for DIN rail installation.
  • Temperature of usage: -20°C ÷ +60°C.
  • Storage temperature: -25°C ÷ +70°C
  • Rating: 14Vrms differential and 8Vrms through earth for CN3 connector, 20Vrms for the CN1 & CN2
  • Maximum Security Voltage(Um): 250Vrms
  • Maximum Security Current (current interruption capability): 1500A
  • Degree of protection: IP20
  • Excitation, Signal and Sense Marking: ATEX II (1)G, II(1)D, I(M1)
  • Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20°C ≤ Tamb ≤ +60°C)

    Please refer to the User Manual for more information.

  • NOTE:
  • Can connect up to 4 Load Cell of 350 Ohm.
  • Combined use of one or more Zener Barriers (1) GD [Ex ia], implies that the Atex marking of the set of barriers must be upgraded (2) GD [Ex ib], as written in the EN 60079-14 normative.

KZBA CASE FEATURES

  • Material: ABS
  • Glands: n.4, ATEX certified.
  • Protection for Case + Barrier:
    for gas:
    - ATEX II 3(1) Ex nAa [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C)
    for dust:
    - ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C).
DOWNLOAD
????
 型号说明
KZBA-1 For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135°C Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT).
 型号说明
DCATEXMB4 ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125°C Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).
Connection cables
 型号说明
LCCB 6芯屏蔽电缆,供传感器或接线盒接线使用。€/米
LCCBA Ex 6-pole shielded cable for RS232 serial port/power supplier, for using in hazardous areas. Price/meter
EXCB6(S6) 传感器防爆6芯屏蔽电缆,供本安区域内使用。€/米

PDF版产品页 All the specifications and images can be subject to variations and upgrades without prior notice.